CRONO SC PORTABLE PUMPS
for palliative treatment

The products described in this website are covered by the EU declaration of conformity, so they are intended for the EU market, with the declared intended purpose.
For non-EU markets such as the US, please contact CANÈ S.p.A. to identify the correct product and the corresponding destination of use.

infusion pumps for palliative treatment Crono SC. Canè
infusion pumps for palliative treatment Crono. Canè

CRONO SC

find out more
infusion pumps for palliative treatment Crono SC 50. Canè
retro infusion pumps for palliative treatment Crono SC 50. Canè

CRONO 50 SC

find out more
CRONO SC with protective flaps

The portable crono SC 50 SC pumps are designed for subcutaneous infusion of palliative care drugs in terminal patients and for subcutaneous infusion of Treprostinil

The pump is indicated in subcutaneous infusions allowing 4 modes of administration:

  1. Continuous

  2. Bolus on request

  3. Clinical bolus (managed by the doctor)

  4. Combined (continuous + bolus on demand + clinical bolus)

The pump is equipped with a keypad lock to prevent incorrect or unauthorised administration.

The liquid crystal display shows physician and patient information on pump programming, operation and diagnostics.

Technical specifications
CRONO SC

Pump dimensions 76 x 49 x 29 mm (3.00 x 1.94 x 1.15 in).
Pump dimensions (with protective wings) 138 x 49 x 29 mm (5.43 x 1.94 x 1.15 in).
Pump weight 115 g (including battery).
Weight (with protective wings) 127 g (4.46 oz.), including battery.
Battery 3 Volt Lithium battery, mod. 123 A (battery life approximately 100 infusions).
Single-use reservoirs Special 10 and 20 ml reservoirs with “Luer-Lock” universal safety fitting.
Administration doses Selectable, from 1 ml to 20 ml in 1 ml increments.
Priming function Only available at the start of the infusion. The maximum volume that can be delivered is 1500 μl in 5 μl increments.
Flow rates selectable From 5 to 2000 μl/h in 1 μl/h increments:
It is possible to disable this function by setting 0 μl/h
Bolus dose Selectable, from 10 μl to 2000 μl in 10 μl increments.
It is possible to disable this function by setting 0 μl.
Clinical bolus Selectable, from 10 μl to 2000 μl in 10 μl increments.
It is possible to disable this function by setting 0 μl.
Minimum interval between bolus doses
    Selectable, from 5 min to 24 hours in the following modes:
  • from 5 minutes to 1 hour in 5 minute increments;
  • from 1 hour to 24 hours in 15 minute increments.
It is possible to disable this function by setting no,Lt.
Bolus doses in one hour From 0 to 12 bolus doses.
The function may be disabled by setting no,Ln.
Flow rate precision +/-2%.
Maximum occlusion pressure 2,5 bar +/- 1,5 (PL1), 4 bar +/-2 (PL2), 5,5 bar +/- 2 (PL3).
Display Liquid crystal display (dimensions 1.1 x 2.8 cm).
Motor Coreless DC motor. The microcontroller controls the rotation speed using an infrared encoder.
Safety circuits They check that the device is functioning correctly, intervening in the event of any fault with acoustic signals and messages on the display.
Anti free-flow system To avoid a non controlled flow inside the delivery set due to the action of the force of gravity.
Supplied standard equipment Ambulatory infusion pump, infusion pump carry-case, elastic belt, collar strap, fabric case, 2 batteries, battery cover opening tool, 2 user manuals (doctor and patient).
Guarantee Two years for manufacturing defects.
infusion pump Crono SC with closed flaps
Crono SC with closed flaps
infusion pump Crono SC with open flaps
Crono SC with open flapse
infusion pump Crono SC witho CRONO STAND
Crono SC with CRONO STAND

accessories CRONO SC

Technical specifications
CRONO SC 50

Pump dimensions 84 x 55 x 42 mm (3.31 x 2.17 x 1.65 in).
Pump weight 139 g (including battery).
Battery 3 Volt Lithium battery, mod. 123 A (battery life approximately 100 infusions).
Dedicated single-use reservoirs With a 50 ml capacity and a “Luer-Lock” universal security attachment.
Partial volume Selectable, from 1 to 50 ml in 1 ml increments.
Priming function Only available at the start of the infusion. The maximum volume that can be delivered is 1.5 ml.
Flow rates Selectable from 0.05 to 5.00 ml/h in 0.01 ml/h increments.
It is possible to disable this function by setting 0 ml/h.
Bolus dose Selectable from 0.10 to 2 ml in 0.02 ml increments.
It is possible to disable this function by setting 0 ml.
Clinical bolus Selectable from 0.10 to 2 ml in 0.02 ml increments.
It is possible to disable this function by setting 0 ml.
Minimum interval between bolus doses
    Can be selected from 5 min to 24 h in the following ways:
  • from 5 min to 1 h in 5 min increments;
  • from 1 h to 24 h in 15 min increments.
It is possible to disable this function by setting no,Lt.
Bolus doses in one hour From 0 to 12 bolus doses.
It is possible to disable this function by setting no,Ln.
Flusso precision +/-3%.
Maximum occlusion pressure 1,8 bar +/-0,8 (PL1) - 2,2 bar +/-1 (PL2) - 3,2 bar +/-1,2 (PL3).
Setting memory The settings are automatically entered in a flash memory which is retained (with the exception of the partial syringe volume) even if the battery is removed from the device.
Display Liquid crystal display (0.43 x 1.1 in, 1.1 x 2.8 cm).
Motor Coreless DC motor. The microcontroller controls the rotation speed using an infrared encoder.
Safety circuits They check that the device is functioning correctly, intervening in the event of any anomaly with acoustic signals and messages on the display.
Anti-free-flow safety system To avoid a non controlled flow inside the delivery set due to the action of the force of gravity.
Supplied standard equipment Ambulatory infusion pump, infusion pump carry-case, elastic belt, collar strap, fabric case, 2 batteries, battery cover opening tool, 2 user manuals (doctor and patient).

accessories CRONO SC 50