Via Cuorgnè 42/a – 10098 Rivoli (TO)

|

mailbox@canespa.it

|

+39 011 957 48 72

CRONO PAR PORTABLE PUMPS
for the treatment of Parkinson's disease

The products described in this website are covered by the EU declaration of conformity, so they are intended for the EU market, with the declared intended purpose.
For non-EU markets such as the US, please contact CANÈ S.p.A. to identify the correct product and the corresponding destination of use.

CRONO PAR serie 4

CRONO PAR serie 3

CRONO PAR with protective flaps

CRONO PAR INFUSION PUMPS

CRONO PAR infusion pumps are used for the treatment of Parkinson's disease with apomorphine (active ingredient), using dedicated 20, 30 and 50 ml syringes called réservoirs.

The small size and light weight of our infusion pumps make them ideal for home use, giving the patient the freedom to carry out daily activities during therapy.

The main technical features of the pump are:
• the possibility of selecting two different device programming modes:
- one defined as FrEE which allows the patient to freely select one of the 3 available flows pre-programmed by the doctor during the day;
- the other defined as Auto which manages, via a clock, a profile of flows pre-programmed by the doctor which change automatically over the course of 24 hours per day.

• the presence of 2 microcontrollers for greater safety and reliability of the instrument.

The feed mechanism acts directly on the piston of the reservoir, allowing the pump to deliver the drug accurately.

For better absorption of the drug, the pump delivers shots of 20 µl at intervals depending on the flow setting.

The time interval between shots decreases proportionally as the programmed flow increases.

The CRONO PAR, CRONO PAR 20 and CRONO PAR 50 are equipped with a liquid crystal display that shows physician and patient information on pump programming, operation and diagnostics.

Technical specifications
CRONO PAR 4-20

Pump dimensions 76 x 49 x 29 mm (138 x 49 x 29 mm with protective wings)
Pump weight 127 g (4.46 oz.), including battery.
Battery Lithium CR 123A 3V (battery life approx. 100 infusions).
Single tank Dedicated, with 10 and 20 ml capacity and "Luer-Lock" universal safety fitting.
Administrable volumes Selectable, from 1 to 20 ml with 1 ml increments.
Flow rate in Free mode (F1, F2, F3)
    Programmable from:
  • 0.05 ml/h to 1.00 ml/h with 0.01 ml/h increments;
  • 1.00 ml/h to 2.00 ml/h with 0.02 ml/h increments;
F2 and F3 may also be programmed to 0.00 ml/h or to OFF (flow rate display disabled).
Selectable flow rates in Free mode 3, all programmable
Flow rate in Auto mode (F1, F2, F3)
    Programmable from:
  • 0.05 ml/h to 1.00 ml/h with 0.01 ml/h increments;
  • 1.00 ml/h to 2.00 ml/h with 0.02 ml/h increments;
Selectable flow rates in Auto mode 4, of which 3 are programmable and one is fixed to 0 ml/h.
Bolus dose volume Programmable from 0.00 to 2.0 ml.
Interval between bolus doses Programmable from 5 minutes to 24 hours. May be disabled.
Flow rate accuracy +/-2%.
Occlusion pressure 3 selectable values. The pump is set to PL2 (4.0 bar +/- 2.0).
Post-occlusion bolus Max. 1.0 ml
Electronic circuit Managed by twin microcontrollers for improved safety.
Storage All selected values are automatically stored in a memory which is retained even if the battery is removed from the device.
Display Colour graphical OLED display, 96x64 pixels.
Motor Coreless DC motor. The microcontroller controls the rotation speed using an infrared encoder.
Keypad lock Two configurable levels.
Safety circuits They ensure that the device is correctly operational. In case of a fault they generate acoustic signals and messages shown on the display.
Pump degree of protection IP 42
Features Ambulatory infusion pump with reservoir, infusion pump carry-case, elastic belt, collar strap, fabric case, 2 batteries, battery cover opening tool and user guide.
Warranty Two years for manufacturing defects.
infusion pump with closed flaps
Crono Par 4-20 with closed flaps
infusion pump with closed flaps
Crono Par 4-20 with open flaps
infusion pump for parkinson's disease Crono Par 4-20
Crono Par 4-20 with syringe 10 ml
infusion pump for parkinson's disease Crono Par 4-20
Crono Par 4-20 with syringe 20 ml
infusion pump for parkinson's disease Crono Par 4-20
Crono Par 4-20 with Crono Bell Adapter
infusion pump for parkinson's disease Crono Par 4-20
Crono Par 4-20 with syringe 20 ml and Crono Bell Adapter

accessories CRONO PAR 4-20

Technical specifications
CRONO PAR 4-30

Pump dimensions 80 x 47 x 30 mm (3.14 x 1.85 x 1.18 in)
Pump weight 127 g (4.46 oz.), including battery.
Battery Lithium CR 123A 3V (battery life approx. 100 infusions).
Single tank Dedicated, with 30 ml capacity and “Luer-Lock” universal safety fitting
Administrable volumes Selectable, from 1 to 20 ml with 1 ml increments.
Flow rate in Free mode (F1, F2, F3)
    Programmable from:
  • 0.05 ml/h to 1.00 ml/h with 0.01 ml/h increments;
  • 1.00 ml/h to 3.00 ml/h with 0.02 ml/h increments;
F2 and F3 may also be programmed to 0.00 ml/h or to OFF (flow rate display disabled).
Selectable flow rates in Free mode 3, all programmable
Flow rate in Auto mode (F1, F2, F3)
    Programmable from:
  • 0.05 ml/h to 1.00 ml/h with 0.01 ml/h increments;
  • 1.00 ml/h to 2.00 ml/h with 0.02 ml/h increments;
Selectable flow rates in Auto mode 4, of which 3 are programmable and one is fixed to 0 ml/h.
Bolus dose volume Programmable from 0.00 to 2.0 ml.
Interval between bolus doses Programmable from 5 minutes to 24 hours. May be disabled.
Flow rate accuracy +/-2%.
Occlusion pressure 3 selectable values. The pump is set to PL2 (4.0 bar +/- 2.0).
Post-occlusion bolus Max. 1.2 ml
Electronic circuit Managed by twin microcontrollers for improved safety.
Storage All selected values are automatically stored in a memory which is retained even if the battery is removed from the device.
Display Colour graphical OLED display, 96x64 pixels.
Motor Coreless DC motor. The microcontroller controls the rotation speed using an infrared encoder.
Keypad lock Two configurable levels.
Safety circuits They ensure that the device is correctly operational. In case of a fault they generate acoustic signals and messages shown on the display.
Pump degree of protection IP 42
Features Ambulatory infusion pump with reservoir, infusion pump carry-case, elastic belt, collar strap, fabric case, 2 batteries, battery cover opening tool and user guide.
Warranty Two years for manufacturing defects.

accessories CRONO PAR 4-30

Technical specifications
CRONO PAR 4-50

Pump dimensions 84 x 55 x 42 mm (3.31 x 2.17 x 1.65 in)
Pump weight 139 g, including battery.
Battery Lithium CR 123A 3V (battery life approx. 100 infusions).
Single tank Dedicated, with 50 ml capacity and “Luer-Lock” universal safety fitting
Flow rate in Free mode (F1, F2, F3)
    Programmable from:
  • 0.05 ml/h to 1.00 ml/h with 0.01 ml/h increments;
  • 1.00 ml/h to 3.00 ml/h with 0.02 ml/h increments;
F2 and F3 may also be programmed to 0.00 ml/h or to OFF (flow rate display disabled).
Selectable flow rates in Free mode 3, all programmable
Flow rate in Auto mode (F1, F2, F3)
    Programmable from:
  • 0.05 ml/h to 1.00 ml/h with 0.01 ml/h increments;
  • 1.00 ml/h to 3.00 ml/h with 0.02 ml/h increments;
Selectable flow rates in Auto mode 4, of which 3 are programmable and one is fixed to 0 ml/h.
Bolus dose volume Programmable from 0.00 to 2.0 ml.
Interval between bolus doses Programmable from 5 minutes to 24 hours. May be disabled.
Flow rate accuracy +/-3%.
Occlusion pressure 3 selectable values. The pump is set to PL2 (2.2 +/- 1.0 bar).
Post-occlusion bolus Max. 1.9 ml
Electronic circuit Managed by twin microcontrollers for improved safety.
Storage All selected values are automatically stored in a memory which is retained even if the battery is removed from the device.
Display Colour graphical OLED display, 96x64 pixels.
Motor Coreless DC motor. The microcontroller controls the rotation speed using an infrared encoder.
Keypad lock Two configurable levels.
Safety circuits They ensure that the device is correctly operational. In case of a fault they generate acoustic signals and messages shown on the display.
Pump degree of protection IP 42
Features Ambulatory infusion pump with reservoir, infusion pump carry-case, elastic belt, collar strap, fabric case, 2 batteries, battery cover opening tool and user guide.
Warranty Two years for manufacturing defects.

accessories CRONO PAR 4-50

Technical specifications
CRONO PAR

Pump dimensions 76 x 49 x 29 mm.
Pump dimensions with protective wings 138 x 49 x 29 mm.
Pump weight (with protective wings) 127 g Battery inclusa
Battery Lithium CR 123A 3V (battery life approx. 100 infusions).
Single-use reservoir Dedicated, with 20 ml capacity and "Luer-Lock" universal safety fitting.
Administration doses Selectable, from 1 to 20 ml with 1 ml increments.
Flows in FrEE mode (F1, F2, F3)
    Programmable from:
  • 0.05 ml/h to 1.00 ml/h with 0.01 ml/h increments;
  • 1.00 ml/h to 3.00 ml/h with 0.02 ml/h increments;
  • 3.00 ml/h to 5.00 ml/h with 0.05 ml/h increments;
• F2 and F3 may also be programmed to 0.00 ml/h or to oFF (flow rate display disabled).
Selectable flow rates in Auto mode 3, all programmable.
Flow rates in Auto mode (F1, F2, F3)
    Programmable from:
  • 0.05 ml/h to 1.00 ml/h with 0.01 ml/h increments;
  • 1.00 ml/h to 3.00 ml/h with 0.02 ml/h increments
  • 3.00 ml/h to 5 ml/h with 0.05 ml/h increments;
Selectable flow rates in Auto mode 4, of which 3 are programmable and 1 is fixed to 0 ml/h.
Bolus dose volume Programmable from 0.00 to 2.00 ml with 0.022 ml increments.
Interval between bolus doses
    Programmable from:
  • 5 minutes to 1 hour with 5 minute increments;
  • 1 hour to 24 hours with 15 minute increments.
This function can be disabled by setting no,Lt.
Flow rate precision +/-2%.
Occlusion pressure 3 selectable values. The pump is set to PL2 (4.0 bar +/-2).
Post-occlusion bolus About 0.9 ml (in PL2 mode).
Electronic circuit Managed by twin microcontrollers with dedicated software.
Memory All selected values are automatically stored in a memory which is retained even if the battery is removed from the device.
Display Liquid Crystal Display (LCD - 11 x 28 mm).
Motor Coreless DC motor. The microcontroller controls the rotation speed using an infrared encoder.
Settings lock Two configurable levels.
Safety circuits They check that the device is correctly operational and trip in case of fault, generating acoustic signals and messages shown on the display.
Protection rating of the pump IP 42
Supplied standard equipment Ambulatory infusion pump with reservoir, infusion pump carry-case, elastic belt, collar strap, fabric case, 2 batteries, battery cover opening tool and user guide.
Guarantee Two years for manufacturing defects.

accessories CRONO PAR

Technical specifications
CRONO PAR 30

Pump dimensions 80 x 47 x 30 mm (3.14 x 1.85 x 1.18 in).
Pump weight 127 g (4.46 oz.), Battery inclusa.
Battery CR 123A 3V al Litio (durata circa 100 infusioni)
Single-use reservoir With a 30 ml capacity and a “Luer-Lock” universal security attachment.
Volumes that can be administered Selectable, from 1 to 30 ml in increments of 1 ml.
Flow rates in FrEE mode (F1, F2, F3)
    Programmable from:
  • 0.05 ml/h to 1.00 ml/h in increments of 0.01 ml/h;
  • 1.00 ml/h to 3.00 ml/h in increments of 0.02 ml/h;
  • 3.00 ml/h to 5.00 ml/h in increments of 0.05 ml/h;
  • F2 and F3 may also be programmed to 0.00 ml/h or to oFF (flow rate display disabled).
Selectable flow rates in FrEE mode 3, all programmable.
Flow rates in Auto mode (F1, F2, F3)
    Programmable from:
  • 0.05 ml/h to 1.00 ml/h in increments of 0.01 ml/h;
  • 1.00 ml/h to 3.00 ml/h in increments of 0.02 ml/h;
  • 3.00 ml/h to 5 ml/h in increments of 0.05 ml/h;
Selectable flow rates in Auto mode 4, of which 3 are programmable and 1 is fixed at 0 ml/h.
Bolus dose volume Programmable from 0.00 to 2.00 ml in increments of 0.033 ml.
Interval between bolus doses
    Programmable from:
  • 5 minutes to 1 hour in increments of 5 minutes;
  • 1 hour to 24 hour in increments of 15 minutes.
It is possible to disable this function by setting no,Lt.
Flow rate precision +/-2%.
Occlusion pressure 3 selectable values. The pump is set to PL2 (3.2 bar +/-1.5).
Post-occlusion bolus About 0.8 ml (in PL2 mode).
Electronic circuit Managed by twin microcontrollers with dedicated software.
Settings memory All settings are automatically entered in a flash memory which is retained even if the device is left without a battery.
Display Liquid Crystal Display.
Motor Coreless DC motor. The microcontroller controls the rotation speed using an infrared encoder.
Settings lock Two configurable levels.
Safety circuits Check that the device is functioning correctly, intervening in the event of any anomaly with acoustic signals and messages on the display.
Supplied standard equipment Ambulatory infusion pump, infuser carry-case, elastic belt, collar strap, fabric case, 2 batteries, battery cover opening tool, user guide.
Guarantee Two years for manufacturing defects.

accessories CRONO PAR 30

Technical specifications
CRONO PAR 50

Pump dimensions 84 x 55 x 42 mm (3.31 x 2.17 x 1.65 in).
Pump dimensions with vanes 139 g (4.47 oz.), including battery.
Battery Lithium CR 123A 3V (battery life approx 100 infusions).
Single-use reservoir With a 50 ml capacity and a “Luer-Lock” universal security attachment.
Administrable volumes Selectable, from 1 to 50 ml in increments of 1 ml.
Flow rates in FrEE mode (F1, F2, F3)
    Programmable from:
  • 0.05 ml/h to 1.00 ml/h in increments of 0.01 ml/h;
  • 1.00 ml/h to 3.00 ml/h in increments of 0.02 ml/h;
  • 3.00 ml/h to 5.00 ml/h in increments of 0.05 ml/h;
  • F2 and F3 may also be programmed to 0.00 ml/h or to oFF (flow rate display disabled)

Selectable flow rates in FrEE mode 3, all programmable.
Flow rates in Auto mode (F1, F2, F3)
    Programmable from:
  • 0.05 ml/h to 1.00 ml/h in increments of 0.01 ml/h;
  • 1.00 ml/h to 3.00 ml/h in increments of 0.02 ml/h;
  • 3.00 ml/h to 5 ml/h in increments of 0.05 ml/h;
Selectable flow rates in Auto mode 4, of which 3 are programmable and 1 is fixed at 0 ml/h.
Bolus dose volume Programmable from 0.00 to 2.00 ml in increments of 0.020 ml.
Interval between bolus doses
    Programmable from:
  • 5 minutes to 1 hour in increments of 5 minutes;
  • 1 hour to 24 hour in increments of 15 minutes.
It is possible to disable this function by setting no,Lt.
Flow delivery accuracy +/-3%.
Occlusion pressure 3 selectable values. The pump is set to PL2 (2.2 bar +/-1).
Post-occlusion bolus About 1.2 ml (in PL2 mode).
Electronic circuit Managed by twin microcontrollers with dedicated software.
Storage All settings are automatically entered in a flash memory which is retained even if the device is left without a battery.
Display Liquid Crystal Display (LCD - 11 x 28 mm; 0.43 x 1.0 in).
Motor Coreless DC motor. The microcontroller controls the rotation speed using an infrared encoder.
Keypad lock Two configurable levels
Safety circuits Check that the device is functioning correctly, intervening in the event of any anomaly with acoustic signals and messages on the display.
Pump degree of protection IP 42
Supplied standard equipment Ambulatory infusion pump with a reservoir, infuser carry-case, elastic belt, collar strap, fabric case, 2 batteries, battery cover opening tool, 1 user guide.
Warranty Two years for manufacturing defects.

accessories CRONO PAR 50