CRONO PAR infusion pumps are used for the treatment of Parkinson's disease with apomorphine (active ingredient), using dedicated 20, 30 and 50 ml syringes called réservoirs.
The small size and light weight of our infusion pumps make them ideal for home use, giving the patient the freedom to carry out daily activities during therapy.
The main technical features of the pump are:
• the possibility of selecting two different device programming modes:
- one defined as FrEE which allows the patient to freely select one of the 3 available flows pre-programmed by the doctor during the day;
- the other defined as Auto which manages, via a clock, a profile of flows pre-programmed by the doctor which change automatically over the course of 24 hours per day.
• the presence of 2 microcontrollers for greater safety and reliability of the instrument.
The feed mechanism acts directly on the piston of the reservoir, allowing the pump to deliver the drug accurately.
For better absorption of the drug, the pump delivers shots of 20 µl at intervals depending on the flow setting.
The time interval between shots decreases proportionally as the programmed flow increases.
The CRONO PAR, CRONO PAR 20 and CRONO PAR 50 are equipped with a liquid crystal display that shows physician and patient information on pump programming, operation and diagnostics.
Pump dimensions | 76 x 49 x 29 mm (138 x 49 x 29 mm with protective wings) |
---|---|
Pump weight | 127 g (4.46 oz.), including battery. |
Battery | Lithium CR 123A 3V (battery life approx. 100 infusions). |
Single tank | Dedicated, with 10 and 20 ml capacity and "Luer-Lock" universal safety fitting. |
Administrable volumes | Selectable, from 1 to 20 ml with 1 ml increments. |
Flow rate in Free mode (F1, F2, F3) |
|
Selectable flow rates in Free mode | 3, all programmable |
Flow rate in Auto mode (F1, F2, F3) |
|
Selectable flow rates in Auto mode | 4, of which 3 are programmable and one is fixed to 0 ml/h. |
Bolus dose volume | Programmable from 0.00 to 2.0 ml. |
Interval between bolus doses | Programmable from 5 minutes to 24 hours. May be disabled. |
Flow rate accuracy | +/-2%. |
Occlusion pressure | 3 selectable values. The pump is set to PL2 (4.0 bar +/- 2.0). |
Post-occlusion bolus | Max. 1.0 ml |
Electronic circuit | Managed by twin microcontrollers for improved safety. |
Storage | All selected values are automatically stored in a memory which is retained even if the battery is removed from the device. |
Display | Colour graphical OLED display, 96x64 pixels. |
Motor | Coreless DC motor. The microcontroller controls the rotation speed using an infrared encoder. |
Keypad lock | Two configurable levels. |
Safety circuits | They ensure that the device is correctly operational. In case of a fault they generate acoustic signals and messages shown on the display. |
Pump degree of protection | IP 42 |
Features | Ambulatory infusion pump with reservoir, infusion pump carry-case, elastic belt, collar strap, fabric case, 2 batteries, battery cover opening tool and user guide. |
Warranty | Two years for manufacturing defects. |
Pump dimensions | 80 x 47 x 30 mm (3.14 x 1.85 x 1.18 in) |
---|---|
Pump weight | 127 g (4.46 oz.), including battery. |
Battery | Lithium CR 123A 3V (battery life approx. 100 infusions). |
Single tank | Dedicated, with 30 ml capacity and “Luer-Lock” universal safety fitting |
Administrable volumes | Selectable, from 1 to 20 ml with 1 ml increments. |
Flow rate in Free mode (F1, F2, F3) |
|
Selectable flow rates in Free mode | 3, all programmable |
Flow rate in Auto mode (F1, F2, F3) |
|
Selectable flow rates in Auto mode | 4, of which 3 are programmable and one is fixed to 0 ml/h. |
Bolus dose volume | Programmable from 0.00 to 2.0 ml. |
Interval between bolus doses | Programmable from 5 minutes to 24 hours. May be disabled. |
Flow rate accuracy | +/-2%. |
Occlusion pressure | 3 selectable values. The pump is set to PL2 (4.0 bar +/- 2.0). |
Post-occlusion bolus | Max. 1.2 ml |
Electronic circuit | Managed by twin microcontrollers for improved safety. |
Storage | All selected values are automatically stored in a memory which is retained even if the battery is removed from the device. |
Display | Colour graphical OLED display, 96x64 pixels. |
Motor | Coreless DC motor. The microcontroller controls the rotation speed using an infrared encoder. |
Keypad lock | Two configurable levels. |
Safety circuits | They ensure that the device is correctly operational. In case of a fault they generate acoustic signals and messages shown on the display. |
Pump degree of protection | IP 42 |
Features | Ambulatory infusion pump with reservoir, infusion pump carry-case, elastic belt, collar strap, fabric case, 2 batteries, battery cover opening tool and user guide. |
Warranty | Two years for manufacturing defects. |
Pump dimensions | 84 x 55 x 42 mm (3.31 x 2.17 x 1.65 in) |
---|---|
Pump weight | 139 g, including battery. |
Battery | Lithium CR 123A 3V (battery life approx. 100 infusions). |
Single tank | Dedicated, with 50 ml capacity and “Luer-Lock” universal safety fitting |
Flow rate in Free mode (F1, F2, F3) |
|
Selectable flow rates in Free mode | 3, all programmable |
Flow rate in Auto mode (F1, F2, F3) |
|
Selectable flow rates in Auto mode | 4, of which 3 are programmable and one is fixed to 0 ml/h. |
Bolus dose volume | Programmable from 0.00 to 2.0 ml. |
Interval between bolus doses | Programmable from 5 minutes to 24 hours. May be disabled. |
Flow rate accuracy | +/-3%. |
Occlusion pressure | 3 selectable values. The pump is set to PL2 (2.2 +/- 1.0 bar). |
Post-occlusion bolus | Max. 1.9 ml |
Electronic circuit | Managed by twin microcontrollers for improved safety. |
Storage | All selected values are automatically stored in a memory which is retained even if the battery is removed from the device. |
Display | Colour graphical OLED display, 96x64 pixels. |
Motor | Coreless DC motor. The microcontroller controls the rotation speed using an infrared encoder. |
Keypad lock | Two configurable levels. |
Safety circuits | They ensure that the device is correctly operational. In case of a fault they generate acoustic signals and messages shown on the display. |
Pump degree of protection | IP 42 |
Features | Ambulatory infusion pump with reservoir, infusion pump carry-case, elastic belt, collar strap, fabric case, 2 batteries, battery cover opening tool and user guide. |
Warranty | Two years for manufacturing defects. |
Pump dimensions | 76 x 49 x 29 mm. |
---|---|
Pump dimensions with protective wings | 138 x 49 x 29 mm. |
Pump weight (with protective wings) | 127 g Battery inclusa |
Battery | Lithium CR 123A 3V (battery life approx. 100 infusions). |
Single-use reservoir | Dedicated, with 20 ml capacity and "Luer-Lock" universal safety fitting. |
Administration doses | Selectable, from 1 to 20 ml with 1 ml increments. |
Flows in FrEE mode (F1, F2, F3) |
|
Selectable flow rates in Auto mode | 3, all programmable. |
Flow rates in Auto mode (F1, F2, F3) |
|
Selectable flow rates in Auto mode | 4, of which 3 are programmable and 1 is fixed to 0 ml/h. |
Bolus dose volume | Programmable from 0.00 to 2.00 ml with 0.022 ml increments. |
Interval between bolus doses |
|
Flow rate precision | +/-2%. |
Occlusion pressure | 3 selectable values. The pump is set to PL2 (4.0 bar +/-2). |
Post-occlusion bolus | About 0.9 ml (in PL2 mode). |
Electronic circuit | Managed by twin microcontrollers with dedicated software. |
Memory | All selected values are automatically stored in a memory which is retained even if the battery is removed from the device. |
Display | Liquid Crystal Display (LCD - 11 x 28 mm). |
Motor | Coreless DC motor. The microcontroller controls the rotation speed using an infrared encoder. |
Settings lock | Two configurable levels. |
Safety circuits | They check that the device is correctly operational and trip in case of fault, generating acoustic signals and messages shown on the display. |
Protection rating of the pump | IP 42 |
Supplied standard equipment | Ambulatory infusion pump with reservoir, infusion pump carry-case, elastic belt, collar strap, fabric case, 2 batteries, battery cover opening tool and user guide. |
Guarantee | Two years for manufacturing defects. |
Pump dimensions | 80 x 47 x 30 mm (3.14 x 1.85 x 1.18 in). |
---|---|
Pump weight | 127 g (4.46 oz.), Battery inclusa. |
Battery | CR 123A 3V al Litio (durata circa 100 infusioni) |
Single-use reservoir | With a 30 ml capacity and a “Luer-Lock” universal security attachment. |
Volumes that can be administered | Selectable, from 1 to 30 ml in increments of 1 ml. |
Flow rates in FrEE mode (F1, F2, F3) |
|
Selectable flow rates in FrEE mode | 3, all programmable. |
Flow rates in Auto mode (F1, F2, F3) |
|
Selectable flow rates in Auto mode | 4, of which 3 are programmable and 1 is fixed at 0 ml/h. |
Bolus dose volume | Programmable from 0.00 to 2.00 ml in increments of 0.033 ml. |
Interval between bolus doses |
|
Flow rate precision | +/-2%. |
Occlusion pressure | 3 selectable values. The pump is set to PL2 (3.2 bar +/-1.5). |
Post-occlusion bolus | About 0.8 ml (in PL2 mode). |
Electronic circuit | Managed by twin microcontrollers with dedicated software. |
Settings memory | All settings are automatically entered in a flash memory which is retained even if the device is left without a battery. |
Display | Liquid Crystal Display. |
Motor | Coreless DC motor. The microcontroller controls the rotation speed using an infrared encoder. |
Settings lock | Two configurable levels. |
Safety circuits | Check that the device is functioning correctly, intervening in the event of any anomaly with acoustic signals and messages on the display. |
Supplied standard equipment | Ambulatory infusion pump, infuser carry-case, elastic belt, collar strap, fabric case, 2 batteries, battery cover opening tool, user guide. |
Guarantee | Two years for manufacturing defects. |
Pump dimensions | 84 x 55 x 42 mm (3.31 x 2.17 x 1.65 in). |
---|---|
Pump dimensions with vanes | 139 g (4.47 oz.), including battery. |
Battery | Lithium CR 123A 3V (battery life approx 100 infusions). |
Single-use reservoir | With a 50 ml capacity and a “Luer-Lock” universal security attachment. |
Administrable volumes | Selectable, from 1 to 50 ml in increments of 1 ml. |
Flow rates in FrEE mode (F1, F2, F3) |
|
Selectable flow rates in FrEE mode | 3, all programmable. |
Flow rates in Auto mode (F1, F2, F3) |
|
Selectable flow rates in Auto mode | 4, of which 3 are programmable and 1 is fixed at 0 ml/h. |
Bolus dose volume | Programmable from 0.00 to 2.00 ml in increments of 0.020 ml. |
Interval between bolus doses |
|
Flow delivery accuracy | +/-3%. |
Occlusion pressure | 3 selectable values. The pump is set to PL2 (2.2 bar +/-1). |
Post-occlusion bolus | About 1.2 ml (in PL2 mode). |
Electronic circuit | Managed by twin microcontrollers with dedicated software. |
Storage | All settings are automatically entered in a flash memory which is retained even if the device is left without a battery. |
Display | Liquid Crystal Display (LCD - 11 x 28 mm; 0.43 x 1.0 in). |
Motor | Coreless DC motor. The microcontroller controls the rotation speed using an infrared encoder. |
Keypad lock | Two configurable levels |
Safety circuits | Check that the device is functioning correctly, intervening in the event of any anomaly with acoustic signals and messages on the display. |
Pump degree of protection | IP 42 |
Supplied standard equipment | Ambulatory infusion pump with a reservoir, infuser carry-case, elastic belt, collar strap, fabric case, 2 batteries, battery cover opening tool, 1 user guide. |
Warranty | Two years for manufacturing defects. |